{
  "icp": {
    "regions": [
      "CN"
    ],
    "use_cases": [
      "epilepsy diagnosis and treatment",
      "deep brain stimulation electrode placement",
      "intracranial tumor and hematoma surgery",
      "stereoelectroencephalography (SEEG) monitoring"
    ],
    "industries": [
      "hospitals",
      "neurosurgery departments"
    ]
  },
  "itha": "0.1",
  "proof": {
    "memberships": [
      {
        "name": "National Key \"Little Giant\" Enterprise (China, 2022)"
      },
      {
        "name": "National Intellectual Property Demonstration Enterprise (China, 2022)"
      }
    ]
  },
  "company": {
    "hq": {
      "city": "Beijing",
      "country": "CN"
    },
    "url": "http://sinovationmed.com",
    "name": "Sinovation Medical",
    "domain": "sinovationmed.com",
    "founded": 2015,
    "same_as": [
      "https://cn.linkedin.com/company/sinovationmedical"
    ],
    "employees": {
      "max": 500,
      "min": 201
    },
    "legal_name": "Sinovation (Beijing) Medical Technology Co., Ltd.",
    "description": "National high-tech enterprise engaged in R&D, production, and sales of precise surgical medical devices for neurosurgery, including neurosurgical robots, neuronavigation systems, intracranial electrodes, robotic surgical microscopes, and MRI-guided laser therapy systems."
  },
  "offerings": [
    {
      "id": "sinobot-x1-neurosurgical-robot",
      "url": "http://sinovationmed.com/product/211.html?lang=en",
      "kind": "hardware",
      "name": "Sinobot X1 Neurosurgical Robot",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Neurosurgical robot integrating Holoshot 3D structured light registration with a fully automatic robotic arm, used for stereotactic biopsy, DBS, and SEEG electrode placement.",
      "extensions": {
        "robotics": {
          "category": "surgical_robot",
          "applications": [
            "biopsy",
            "deep_brain_stimulation",
            "stereoelectroencephalography"
          ],
          "spec_version": "0.1",
          "repeatability_mm": {
            "max": 0.5,
            "min": 0.5
          }
        }
      },
      "certifications": [
        {
          "id": "fda_510k",
          "issuer": "US Food and Drug Administration",
          "status": "third_party_certified",
          "evidence_url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm?ID=K220072"
        }
      ]
    },
    {
      "id": "x1000-neuro-spinal-surgical-robot",
      "url": "http://sinovationmed.com/product/230.html?lang=en",
      "kind": "hardware",
      "name": "X1000 Neuro-Spinal Surgical Robot",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Three-module surgical robot system combining neurosurgical robot positioning, neuronavigation, and spine robot positioning for brain and spine procedures.",
      "extensions": {
        "robotics": {
          "category": "surgical_robot",
          "applications": [
            "deep_brain_stimulation",
            "stereoelectroencephalography",
            "spine_surgery"
          ],
          "spec_version": "0.1"
        }
      },
      "certifications": [
        {
          "id": "nmpa",
          "issuer": "China National Medical Products Administration",
          "status": "third_party_certified"
        }
      ]
    },
    {
      "id": "ns1-neuronavigation-system",
      "url": "http://sinovationmed.com/product/210.html?lang=en",
      "kind": "hardware",
      "name": "NS1 Series Neuronavigation System",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Infrared optical neuronavigation platform with SinoPlan surgical planning software, compatible with CT, MRI, PET, CTA, and MRA imaging, for brain lesion resection and biopsy.",
      "extensions": {
        "robotics": {
          "category": "surgical_navigation_system",
          "applications": [
            "inspection"
          ],
          "spec_version": "0.1",
          "repeatability_mm": {
            "max": 1
          }
        }
      }
    },
    {
      "id": "q300-miniature-neurosurgical-robot",
      "url": "http://sinovationmed.com/product/209.html?lang=en",
      "kind": "hardware",
      "name": "Q300 Series Neurosurgical Miniature Robot",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Miniature neurosurgical robot combining robotic stereotaxis with intraoperative infrared navigation for minimally invasive and open cranial procedures.",
      "extensions": {
        "robotics": {
          "category": "surgical_robot",
          "applications": [
            "biopsy"
          ],
          "spec_version": "0.1",
          "repeatability_mm": {
            "max": 1
          }
        }
      },
      "certifications": [
        {
          "id": "nmpa",
          "issuer": "China National Medical Products Administration",
          "status": "third_party_certified"
        }
      ]
    },
    {
      "id": "es-100-robotic-surgical-microscope",
      "url": "http://sinovationmed.com/product/232.html?lang=en",
      "kind": "hardware",
      "name": "ES-100 Robotic Surgical Microscope",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Robotic exoscope with 4K-3D imaging, a 7-axis robotic arm, and multi-mode fluorescence angiography (sodium fluorescein, 5-ALA, ICG) for neurosurgery, spine, ENT, and reconstructive procedures.",
      "extensions": {
        "robotics": {
          "axes": 7,
          "category": "surgical_microscope",
          "reach_mm": {
            "max": 1500,
            "min": 1500
          },
          "applications": [
            "inspection"
          ],
          "spec_version": "0.1"
        }
      }
    },
    {
      "id": "ls1-mrglitt-system",
      "url": "http://sinovationmed.com/product/208.html?lang=en",
      "kind": "hardware",
      "name": "LS1 Magnetic Resonance-Guided Laser Interstitial Thermal Therapy System",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "MRI-guided laser interstitial thermal therapy system placing a laser fiber into intracranial lesions under real-time MRI temperature monitoring, for epilepsy and brain tumors.",
      "extensions": {
        "robotics": {
          "category": "support_service",
          "applications": [
            "material_removal"
          ],
          "spec_version": "0.1"
        }
      }
    },
    {
      "id": "intracranial-electrodes",
      "url": "http://sinovationmed.com/product/212.html?lang=en",
      "kind": "consumable",
      "name": "Intracranial Electrodes",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Family of implantable intracranial electrodes (cortical strip/grid, RF-TC depth, flexible sphenoidal) for SEEG monitoring, cortical mapping, and radiofrequency thermocoagulation in epilepsy care.",
      "extensions": {
        "robotics": {
          "category": "sensor",
          "applications": [
            "inspection"
          ],
          "spec_version": "0.1"
        }
      }
    },
    {
      "id": "epilepsy-diagnosis-treatment-solutions",
      "url": "http://sinovationmed.com/product/216.html?lang=en",
      "kind": "service",
      "name": "Clinical Diagnosis and Treatment Solutions for Drug-Resistant Epilepsy",
      "role": "manufacturer",
      "pricing": {
        "model": "quote"
      },
      "summary": "Combined clinical use of Sinovation's neurosurgical robots, neuronavigation systems, and intracranial electrodes to support diagnosis and treatment of drug-resistant epilepsy."
    }
  ],
  "engagement": {
    "url": "http://sinovationmed.com/?lang=en",
    "email": "international@sinovationmed.com",
    "phone": "+86-10-67088936",
    "methods": [
      "consultation",
      "quote_request"
    ]
  },
  "extensions": {
    "robotics": {
      "roles": [
        "robot_manufacturer",
        "component_manufacturer",
        "software_vendor"
      ],
      "service_area": [
        "CN"
      ],
      "spec_version": "0.1"
    }
  },
  "updated_at": "2026-09-04"
}